Active Standby Failover
This section describes Active/Standby failover and includes the following topics:
• Active/Standby Failover Overview, page 14-6
• Primary/Secondary Status and Active/Standby Status, page 14-6
• Device Initialization and Configuration Synchronization, page 14-7
• Command Replication, page 14-7
• Failover Triggers, page 14-8
• Failover Actions, page 14-9
Active/Standby Failover Overview
Active/Standby failover lets you use a standby security appliance to take over the functionality of a failed unit. When the active unit fails, it changes to the standby state while the standby unit changes to the active state. The unit that becomes active assumes the IP addresses (or, for transparent firewall, the management IP address) and MAC addresses of the failed unit and begins passing traffic. The unit that is now in standby state takes over the standby IP addresses and MAC addresses. Because network devices see no change in the MAC to IP address pairing, no ARP entries change or time out anywhere on the network.
Note For multiple context mode, the security appliance can fail over the entire unit (including all contexts) but cannot fail over individual contexts separately.
Primary/Secondary Status and Active/Standby Status
The main differences between the two units in a failover pair are related to which unit is active and which unit is standby, namely which IP addresses to use and which unit actively passes traffic.
However, a few differences exist between the units based on which unit is primary (as specified in the configuration) and which unit is secondary:
• The primary unit always becomes the active unit if both units start up at the same time (and are of equal operational health).
• The primary unit MAC addresses are always coupled with the active IP addresses. The exception to this rule occurs when the secondary unit is active, and cannot obtain the primary unit MAC addresses over the failover link. In this case, the secondary unit MAC addresses are used.
Device Initialization and Configuration Synchronization
Configuration synchronization occurs when one or both devices in the failover pair boot. Configurations are always synchronized from the active unit to the standby unit. When the standby unit completes its initial startup, it clears its running configuration (except for the failover commands needed to communicate with the active unit), and the active unit sends its entire configuration to the standby unit.
The active unit is determined by the following:
• If a unit boots and detects a peer already running as active, it becomes the standby unit.
• If a unit boots and does not detect a peer, it becomes the active unit.
• If both units boot simultaneously, then the primary unit becomes the active unit and the secondary unit becomes the standby unit.
Note If the secondary unit boots without detecting the primary unit, it becomes the active unit. It uses its own MAC addresses for the active IP addresses. However, when the primary unit becomes available, the secondary unit changes the MAC addresses to those of the primary unit, which can cause an interruption in your network traffic. To avoid this, configure the failover pair with virtual MAC addresses. See the "Configuring Virtual MAC Addresses" section on page 14-26 for more information.
When the replication starts, the security appliance console on the active unit displays the message "Beginning configuration replication: Sending to mate," and when it is complete, the security appliance displays the message "End Configuration Replication to mate." During replication, commands entered on the active unit may not replicate properly to the standby unit, and commands entered on the standby unit may be overwritten by the configuration being replicated from the active unit. Avoid entering commands on either unit in the failover pair during the configuration replication process. Depending upon the size of the configuration, replication can take from a few seconds to several minutes.
On the standby unit, the configuration exists only in running memory. To save the configuration to Flash memory after synchronization:
• For single context mode, enter the write memory command on the active unit. The command is replicated to the standby unit, which proceeds to write its configuration to Flash memory.
• For multiple context mode, enter the write memory all command on the active unit from the system execution space. The command is replicated to the standby unit, which proceeds to write its configuration to Flash memory. Using the all keyword with this command causes the system and all context configurations to be saved.
Note Startup configurations saved on external servers are accessible from either unit over the network and do not need to be saved separately for each unit. Alternatively, you can copy the contexts on disk from the active unit to an external server, and then copy them to disk on the standby unit, where they become available when the unit reloads.
Command Replication
Command replication always flows from the active unit to the standby unit. As commands are entered on the active unit, they are sent across the failover link to the standby unit. You do not have to save the active configuration to Flash memory to replicate the commands.
The following commands are replicated to the standby unit:
• all configuration commands except for the mode, firewall, and failover lan unit commands
• copy running-config startup-config
• write memory
The following commands are not replicated to the standby unit:
• all forms of the copy command except for copy running-config startup-config
• all forms of the write command except for write memory
• failover lan unit
• firewall
Note Changes made on the standby unit are not replicated to the active unit. If you enter a command on the standby unit, the security appliance displays the message **** warning **** Configuration
Replication is NOT performed from Standby unit to Active unit. Configurations are no longer synchronized. This message displays even when you enter many commands that do not affect the configuration.
If you enter the write standby command on the active unit, the standby unit clears its running configuration (except for the failover commands used to communicate with the active unit), and the active unit sends its entire configuration to the standby unit.
For multiple context mode, when you enter the write standby command in the system execution space, all contexts are replicated. If you enter the write standby command within a context, the command replicates only the context configuration.
Replicated commands are stored in the running configuration. To save the replicated commands to the Flash memory on the standby unit:
• For single context mode, enter the copy running-config startup-config command on the active unit. The command is replicated to the standby unit, which proceeds to write its configuration to Flash memory.
• For multiple context mode, enter the copy running-config startup-config command on the active unit from the system execution space and within each context on disk. The command is replicated to the standby unit, which proceeds to write its configuration to Flash memory. Contexts with startup configurations on external servers are accessible from either unit over the network and do not need to be saved separately for each unit. Alternatively, you can copy the contexts on disk from the active unit to an external server, and then copy them to disk on the standby unit.
Failover Triggers
The unit can fail if one of the following events occurs:
• The unit has a hardware failure or a power failure.
• The unit has a software failure.
• Too many monitored interfaces fail.
I Chapter 14 Configuring Failover_
Understanding Failover H
• The no failover active command is entered on the active unit or the failover active command is entered on the standby unit.
Failover Actions
In Active/Standby failover, failover occurs on a unit basis. Even on systems running in multiple context mode, you cannot fail over individual or groups of contexts.
Table 14-1 shows the failover action for each failure event. For each failure event, the table shows the failover policy (failover or no failover), the action taken by the active unit, the action taken by the standby unit, and any special notes about the failover condition and actions.
|
Failure Event |
Policy |
Active Action |
Standby Action |
Notes |
|
Active unit failed (power or hardware) |
Failover |
Mark active as failed |
No hello messages are received on any monitored interface or the failover link. |
|
|
Formerly active unit recovers |
No failover |
Become standby |
No action |
None. |
|
Standby unit failed (power or hardware) |
No failover |
Mark standby as failed |
n/a |
When the standby unit is marked as failed, then the active unit does not attempt to fail over, even if the interface failure threshold is surpassed. |
|
Failover link failed during operation |
No failover |
Mark failover interface as failed |
Mark failover interface as failed |
You should restore the failover link as soon as possible because the unit cannot fail over to the standby unit while the failover link is down. |
|
Failover link failed at startup |
No failover |
Mark failover interface as failed |
Become active |
If the failover link is down at startup, both units become active. |
|
Stateful Failover link failed |
No failover |
No action |
No action |
State information becomes out of date, and sessions are terminated if a failover occurs. |
|
Interface failure on active unit above threshold |
Failover |
Mark active as failed |
Become active |
None. |
|
Interface failure on standby unit above threshold |
No failover |
No action |
Mark standby as failed |
When the standby unit is marked as failed, then the active unit does not attempt to fail over even if the interface failure threshold is surpassed. |