Wire Gauge and Resistance

Most telephone cable installed since 1980 is either 24 AWG or 26 AWG. 26-gauge wire has a slightly smaller diameter than 24-gauge, and many more pairs can be placed in the same space required by 24-gauge wire. (The international equivalent diameters are 0.5 and 0.4 mm.) Before 1970, and especially before 1960, 22-gauge wire was often used. In the 1950s, 19-gauge wire was occasionally installed. The difference between DC loop resistance on an 18,000-foot pair of 19-gauge wire and 26-gauge wire is radical. Smaller wire gauges became popular as lower loop currents were required to obtain acceptable telephone performance, and as the need for many more wire pairs in the cables and conduits developed.
A quick comparison of DC resistance further illustrates the difference between 24- and 26-gauge wire: 24-gauge wire has a resistance of 26 Ohms per 1000 feet, and 26-gauge wire has a resistance of 41 Ohms per 1000 feet, measured at a temperature of 25C/75F. A telephone line is a DC loop, so 18,000 feet of cable is actually a loop of 36,000 feet of copper wire. A significant change in resistance occurs from cool to hot ambient temperature, especially when using aerial cable that is exposed to the sun. Therefore, DSL performance can change between midnight and noon in some climates, simply because of increased resistance that causes increased attenuation as the cable heats between midnight and noon. Recall that as resistance (and correlative attenuation) increases, SNRs degrade.
Continue reading here: Nsp
Was this article helpful?
Readers' Questions
-
KEEGAN1 month ago
- Reply
-
frank1 month ago
- Reply
-
fatima1 month ago
- Reply
-
Salvatore2 months ago
- Reply
-
sofia7 months ago
- Reply
-
HAZEL7 months ago
- Reply