Example 185 Using the show module Command to Determine the Msfc Rp Virtual Slot Number

Cat6000 (enable) show module Mod Slot Ports Module-Type Model Status---------

------------------------------------------------------- 1 1 2 1000BaseX Supervisor WS-

X6K-SUP1-2GE ok 15 1 1 Multilayer Switch Feature WS-F6001-RSFC ok 3 3 24 100BaseFX MM Ethernet WS-X6224-100FX-MT ok 4 4 24 100BaseFX MM Ethernet WS-X6224- 100FX-MT ok 5 5 8 1000BaseX Ethernet WS-X6408-GBIC ok 6 6 48

10/100BaseTX (RJ-45) WS-X6248-RJ-45 ok Mod Module-Name Serial-Num----------

----------------------- 1 SAD03070893 15 3024158973 3 SAD03080262 4

SAD03080421 5 SAD03040595 6 SAD03142742 Mod MAC-Address(es) Hw Fw Sw ---

----------------------------------------------------------------------- 1 00-50-54-6c-a9-

e6 to 00-50-54-6c-a9-e7 1.4 5.1(1) 4.2(0.24)DAY35 00-50-54-6c-a9-e4 to 00-50-54-6c-a9-e5 00-50-3e-05-58-00 to 00-50-3e-05-5b-ff 15 00-50-73-ff-ab-00 to 00-50-73-ff-ab-ff 0.305 12.0(2.6)T 12.0(2.6)TW6(0.14) 3 00-50-54-6c-a5-34 to 00-50-54-6c-a5-4b 1.2 4.2(0.24)V 4.2(0.24)DAY35 4 00-50-54-6c-a4-74 to 00-50-54-6c-a4-8b 1.2 4.2(0.24)V 4.2(0.24)DAY35 5 00-50-f0-a8-44-64 to 00-50-f0-a8-44-6b 1.4 4.2(0.24)V 4.2(0.24)DAY35 6 00-50-f0-aa-58-38 to 00-50-f0-aa-58-67 1.0

4.2(0.24)V 4.2(0.24)DAY35 Mod Sub-Type Sub-Model Sub-Serial Sub-Hw-----------

--------------------------------------------------- 1 l3 Switching Engine WS-F6K-PFC

SAD03152173 0.205 Cat6000 (enable)

Notice that the second line (marked in bold type) under the uppermost headers in Example 18-5 lists the MSFC RP as a Multilayer Switch Feature WS-F6001- RSFC

in Slot 15.

Note

Example 18-5 shows the output of a 6009/6509 containing a single Supervisor in Slot 1. An MSFC physically located in Slot 2 uses a virtual slot number of 16. A 6006/6506 also uses Slots 15 and 16.

Therefore, by entering the command session 15, you are connected to the MSFC RP where you can enter router commands.

Although the numbering pattern is fairly simple, use the show module command to determine and remember the virtual slot numbers used by MSFC RP modules.

Was this article helpful?

0 0